Camper van electrics: battery size, fuses and a 12 V cable size chart

A 12 V system is sized in four steps: add up what you use in a day, choose a battery that covers it, check that solar and driving bring it back, then give every cable a fuse and a cross-section. The figures below are a worked example for a typical small camper; in the planner you put in your own devices.

Open the planner Free, in your browser, no account needed

1. What you use in a day

ConsumerPowerHours a dayEnergy a day
Compressor fridge (runs about a third of the time)45 W8360 Wh
LED lights15 W460 Wh
Phones, tablet, camera20 W360 Wh
Laptop60 W2120 Wh
Water pump40 W0.28 Wh
Roof fan15 W345 Wh
Total653 Wh

2. How big the battery has to be

A 100 Ah lithium (LiFePO4) battery holds about 1,152 Wh you can use, because nearly all of it may be drawn (90 %). A lead (AGM) battery of the same size gives only about 600 Wh, because it should not go below half. With the consumption above that is 1.8 days on lithium and 0.9 days on AGM with nothing coming in.

3. What comes back in

A solar panel lying flat on the roof delivers roughly three quarters of its rating for each hour of full sun: about 1 hour a day in a northern winter, 3 in spring and autumn, 5 in summer. A 200 W panel therefore brings about 150 Wh in winter, 450 Wh in spring and 750 Wh in summer. A 30 A charging booster adds about 405 Wh for every hour of driving. Compare that with the daily total from step 1.

4. Fuses and cable sizes

Every cable gets its own fuse, as close to the battery or fuse box as possible. The fuse protects the cable, not the device: it sits about a quarter above the running current, and the cable must be able to carry what the fuse lets through. On 12 V the length matters as much as the current, because a thin, long cable loses voltage: the sizes here keep the loss at or below 3 % over the way there and back.

Cable runCurrentFuseCable
Battery to fuse box12.5 A20 A4 mm²
Solar charge controller to battery15.4 A20 A4 mm²
Starter battery to charging booster34.5 A50 A25 mm²
Compressor fridge (runs about a third of the time)3.8 A5 A1.5 mm²
LED lights1.3 A3 A0.75 mm²
Phones, tablet, camera1.7 A3 A0.75 mm²
Laptop5 A7.5 A2.5 mm²
Water pump3.3 A5 A1.5 mm²
Roof fan1.3 A3 A0.75 mm²

12 V cable size chart

Copper cross-section in mm² for a given current and one-way cable length, for at most 3 % voltage loss at 12 V, and never thinner than the fuse allows.

CurrentFuse1 m2 m4 m6 m8 m
5 A7.5 A1.5 mm²1.5 mm²2.5 mm²4 mm²4 mm²
10 A15 A4 mm²4 mm²4 mm²6 mm²10 mm²
15 A20 A4 mm²4 mm²6 mm²10 mm²16 mm²
20 A25 A6 mm²6 mm²10 mm²16 mm²16 mm²
30 A40 A10 mm²10 mm²16 mm²25 mm²25 mm²
50 A80 A16 mm²16 mm²25 mm²35 mm²50 mm²

Motors and compressors draw more when they start, inverters draw very high currents, and every maker states the fuse and cable for their device: those figures win. This page is a planning aid, not a wiring diagram; 230 V installations belong in the hands of an electrician. See the terms of use.

Size your own system

In VanPlanner you list your own consumers, battery, solar and booster, and get the daily balance, a wiring overview and the fuse and cable size for every run.

Open the planner Free, in your browser, no account needed